The best 3 phase double convertion UPS

Features :

  • UPS controlled by Digital Signal Processor (DSP)
  • Sine wave Pulse Width Modulation (SPWM)
  • High Resolution 320 x 240 dots graphs LCD Display
  • Automatica Battery Management and charging system
  • Wide input Voltage range 176V~264V
  • Pure sine wave output less than 3% THD
  • UPS status display on LED flowchart
  • Smart RS-232 or RS-485 communication port
  • Accept two AC source input (option)
  • SNMP management capability (option)
  • Intranet/Internet management function capability (option)
  • 20KHz high frequency inverter
  • Versatile modular design
  • Expandable battery run time
  • Generator compatible
  • IGBT inverter design
  • Double conversion on-line system
  • Multi-function LCD display
  • Cold start function (DC power on)
  • Battery test on AC mode
  • Accepted 100% Unbalanced load
  • Remote control panel (option)
  • IBM AS-400 interface communication port (option)

MODEL NAME ONL-10K33 ONL-15K33 ONL-22.5K33
CAPACITY 10KVA 15KVA 22.5KVA
POWER 8KW 12KW 18KW
P.F. 0.8
INPU Phase 3 Phase 3 wire / 3 Phase 4 wire and ground
Voltage range 208V / 120V or 380V / 220V +/-20%
Frequency range Auto-sensing, 50Hz / 60Hz +/-5Hz
Way of rectifier 3 phase 6 pulses or 12 pulses (option)
Efficiency of rectifier >97%
EFFICIENCY OF INVERTER >88%
TOTAL EFFICIENCY >85%
OUTPUT Phase 3 phase 4 wire and ground
Voltage range 208V / 120V or 380V / 220V
Voltage regulation +/-1%
Transient state Return to 90% with 4 cycles
Overload capacity Bypass after 30 min while overload > 100% < 125%
  Bypass after 30 sec while overload = 125% < 150%
  Bypass after 30 cycles while overloadexceed >=150%
Way of inverter Sine wave modulated from 20K Hz pulse by DSP control
Frequency 50Hz / 60Hz
Frequency Regulation +/- 1%
Range of phase lock +/- 5Hz
Range of lock released > +/- 5Hz
Range of lock back +/- 3Hz
Wave Sine wave
Load crest factor 3 : 1
Total harmonic
distortion
Less 3% for linear load
STATIC SWITCH Transfer way When inverter and utility are synchronized at same phase and voltages, bypass to inverter
Transfer time Bypass to inverter 0ms
Normal state, inverter to bypass 0ms
Efficiency >99%
Frequency Stability +/- 0.5%
CHARGER Voltage DC410V
Current Current can be adjusted at 3A, 5A, 10A, 15A, 20A, 30A automatically
Charging period Return to 90% from 100% exhausted battery within 8 hours (depending on type of batteries)
UNIT Battery type Bank with 12V x 30pcs for DC410V version
Backup time Depending on type of batteries
Noise Less than 60dBA from the surface of 1m away
Environment Operating Temperature 0 - 40 deg.
Storage Temperature -25 ~ 55 deg.
Ambient operation 3,500 meters max. elevation, 0-95% humidity non-condensing
Physical size
W x D x H mm
WxDxH 208/120 520 x 875 x 1010 mm 530 x 960 x 1180 mm
380/220
Weight Net Weight (Kgs) 208/120 427Kg 463Kg 457Kg
380/220q 333kg 343Kg 345Kg